ABB REF610C11LCLR 60HZ relay integrated protection device PLC module

ABB REF610C11LCLR 60HZ relay integrated protection device PLC module

ABB REF610C11LCLR 60HZ relay integrated protection device PLC module

Brand ABB color standard Application Industrial height 256mm rated current 230mA
Protection Level IP45 Suitable for motor power 358KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part Number REF610C
Applicable pipe 2 Whether imported is weighing 1.89 kg can be sold nationwide

ABB REF610C11LCLR 60HZ relay integrated protection device PLC module

Brand ABB color standard Application Industrial height 256mm rated current 230mA
Protection Level IP45 Suitable for motor power 358KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part Number REF610C
Applicable pipe 2 Whether imported is weighing 1.89 kg can be sold nationwide

ABB REF610C11LCLR 60HZ relay integrated protection device PLC module

When necessary, PCM600 is provided according to application requirements.

Analog channels have fixed connections to different functional blocks

In the standard configuration of IED. The exception to this rule is 12

Analog channels that can be used for interference recorder functions. These channels are optional and part of the disturbance recorder parameter setting. Analog channels are assigned to different functions. Common signal

The three-phase current is represented by the 3I label. The signal marked Io indicates the residual current measured through the summing connection of the phases. The current transformer phase discontinuity protection (PDNPSTOC1) interrupts the power supply for normal three-phase loads, for example in the event of a power outage

Command the situation. The phase discontinuity protection of the operating signal is connected to the main trip, also connected to the alarm LED and the disturbance recorder Thermal overload protection (T1PTTR1) in overload situations. The operating signal of the thermal overload protection is connected to the main trip and also to the alarm LED. LED 4 is used for phase discontinuity protection operation indication, the same sequence as the negative overcurrent protection operation indication, and LED 5 is used for thermal overload protection alarm indication.

ABB REF610C11LCLR 60HZ relay integrated protection device PLC module

ABB 83SR04C-E
ABB 83SR06B-E
ABB AB91-1 HESG437479R1 HESG437899
ABB AC800M 3BSE053240R1 PM891
ABB AFC094AE02
ABB AI620
ABB AI625
ABB AIM0016
ABB AM801F
ABB AM811F
ABB AO610
ABB ASE2UDC920AE01
ABB AV94A HESG440940R11 HESG216791/A
ABB BCU-12
ABB BIO0003
ABB BPL0001
ABB BRC3000A
ABB CB801
ABB CI534V02 3BSE010700R1
ABB CI535V30 3BSE022162R1
ABB CI541V1 3BSE014666R1