5SHY3545L0016 3BHB020720R0002 ABB High-power electrical components



Article number :5SHY3545L0016
Communication protocol ABB’s DriveBus
Master or slave Master
Transmission speed 8 Mbit/s
Line redundancy No
Module redundancy No
Hot Swap Yes
Used together with HI Controller No
Contact : Zoe
WhatsApp: +86-15359298206
Phone: +86-15359298206 (Wechat)
E-mail: 2851759107@qq.com
QQ : 2851759107
main parameter
electric current
1. Rated on-state current (IT) is the maximum stable working current, commonly known as current. The IT of commonly used silicon controlled rectifier is generally from one ampere to tens of amperes.
2. Reverse repetitive peak voltage (VRRM) or off state repetitive peak voltage (VDRM), commonly known as withstand voltage. The VRRM/VDRM of commonly used silicon controlled rectifier is generally from several hundred volts to one thousand volts.
3. Control pole trigger current (IGT), commonly known as trigger current. The IGT of commonly used silicon controlled rectifier is generally several microamps to tens of milliamps.
4. The average value of the current allowed to pass through the cathode and anode under the specified ambient temperature and heat dissipation conditions.
purpose
The most basic use of ordinary thyristor is controllable rectification. The familiar diode rectifier circuit belongs to uncontrolled rectifier circuit. If the diode is replaced by a thyristor, a controllable rectifier circuit can be formed. Take the simplest single-phase half-wave controllable rectifier circuit as an example. During the positive half cycle of the sinusoidal AC voltage U2, if the control pole of VS does not input the trigger pulse Ug, VS still cannot be connected. Only when U2 is in the positive half cycle and the trigger pulse Ug is applied to the control pole, the thyristor is triggered to be connected. Draw its waveforms (c) and (d). Only when the trigger pulse Ug arrives, the load RL will have voltage UL output. Ug arrived early, and the thyristor turned on early; When Ug arrives late, the thyristor will turn on later. By changing the arrival time of the trigger pulse Ug on the control pole, the average value UL of the output voltage on the load can be adjusted. In electrical technology, the half cycle of alternating current is often set at 180 °, which is called electrical angle. In this way, the electrical angle experienced from zero to the moment of the trigger pulse is called the control angle in each positive half cycle of U2 α; The electrical angle of thyristor conduction in each positive half cycle is called conduction angle θ。 Obviously, α and θ Both are used to indicate the conduction or blocking range of the thyristor during the half cycle of bearing the forward voltage. By changing the control angle α Or conduction angle θ, The controllable rectification is realized by changing the average value UL of the pulse DC voltage on the load.
1: Low-power plastic-encapsulated bidirectional thyristor is commonly used as acoustooptic lighting system. Rated current: IA is less than 2A.
2: large; Medium-power plastic-sealed and iron-sealed thyristor are commonly used as power-type controllable voltage regulating circuits. Like adjustable voltage output DC power supply, etc.
3: High-power high-frequency thyristor is commonly used in industry; High frequency smelting furnace, etc.



Other relevant models
5SHX0360D0001 IGCT MODULE 38 MM/6KV, HL000384P0101, 3BHB004027R0101
5SHX0660F0001 3BHB003387R0101 GVC703AE01 3BHL00386P0101
5SHX0660F0002 3BHE022333R0101
5SHX06F6004 3BHB003387R0101/5SXE05-0151/3BHB003151P104
5SHX0845F0001 3BHL000385P0101 3BHB003387R0101 5SXE05-0151
5SHX1060H0001 3BHB003230R0101 3BHL000392P0101
5SHX1060H0003 3BHE024415R0101 3BHB020538R0001 GVC714A101
5SHX10H6004
5SHX1445H0001 3BHL000391P0101
5SHX14H4502 3BHB003230R0101 5SXE05-0152 3BHB003023P201
5SHX1960L0004 3BHL000390P0104
5SHX2645L0002 3HB012961R0001
5SHX2645L0004 3BHL000389P0104
5SHX2645L0006 3BHB012961R0002
5SHY3545L0002 3BHE009681R0101 CVC750BE101
KUC711AE 3BHB004661R0001
KUC711AE01 3BHB004661R0001
KUC711AE101 3BHB004661R0101
KUC720AE 3BHB000652R0001
5SHY3545L0014
5SHY3545L0016 3BHB020720R0002
5SHY35L4520
5SHY4045L0004 3BHB021400R0002
5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101
5SHY5045L0020 AC10272001R0101 5SXE10-0181
5SHY5055L0002 3BHE019719R0101 GVC736BE101
5SHX1060H0003
ABB operation screen PP800 V4.0
PP820 function key panel,FSTN 260*64 pixels,pictures and characters,color
PP826,5.7’function key panel,CSTN 320*280 pixels,pictures and characters,color
PP836,6.5″TFT640*480 pixels,picture and text,color
PP846,10.4″TFT800*600 pixels,picture and text,color
PP815,3.5″TFT320*280 pixels,pictures and characters,color
PP825,5.7″CSTN 320*280 pixels,pictures and characters,color
PP835,6.5″LCD640*480 pixels,picture and text,touch screen,color
PP845,10.4″TFT800*600 pixels,picture and text,touch screen,color
PP865,15″TFT1024*768 pixels,picture and text,touch screen,color
ABB operation screen PP800 V5.0 V6.0
PP820A function key panel,FSTN 260*64 pixels,pictures and characters,color
PP826A,5.7’function key panel,CSTN 320*280 pixels,pictures and characters,color
PP836A,6.5″TFT640*480 pixels,picture and text,color
PP846A,10.4″TFT800*600 pixels,picture and text,color
PP815A,3.5″TFT320*280 pixels,pictures and characters,color
PP825A,5.7″CSTN 320*280 pixels,pictures and characters,color
PP835A,6.5″LCD640*480 pixels,picture and text,touch screen,color
PP845A,10.4″TFT800*600 pixels,picture and text,touch screen,color
PP865A,15″TFT1024*768 pixels,picture and text,touch screen,color