GE

GE IC670GBI002 distributed I/O connector

GE IC670GBI002 distributed I/O connector

Brand ABB color standard Application Industrial height 427mm rated current 537mA
Protection level IP45 Suitable for motor power 86KW Application Site Power Industry BOM Number GJR2391500R1220 Power industry HIEE401782R0001 Part Number IC670GBI002
Applicable pipe 2 Whether imported is weighing 4.67 kg can be sold nationwide

Get A Quote
Contact Us

GE IC670GBI002 distributed I/O connector

Brand ABB color standard Application Industrial height 427mm rated current 537mA
Protection level IP45 Suitable for motor power 86KW Application Site Power Industry BOM Number GJR2391500R1220 Power industry HIEE401782R0001 Part Number IC670GBI002
Applicable pipe 2 Whether imported is weighing 4.67 kg can be sold nationwide

GE IC670GBI002 distributed I/O connector

GE Multilin’s 369-HI-R-0-0-0 motor management relay is designed to control and protect large and medium sized motors. 369 includes protection features such as automatic undervoltage restart, reverse power, starter failure, kVA requirement, kvar requirement, kW requirement, current requirement, spin detection, self-test/service, travel counter, RRTD communication loss, RTD disconnect/disconnect, Short circuit/low temperature RTD, ambient RTD, acceleration timer, mechanical plugging, etc.
Product description
The 369-HI-R-0-0-0 is a motor management relay manufactured by GE Multilin. The control power supply is 50-300 volts DC / 40-265 volts AC. The relay has 12 optional RTD inputs. This unit does not include metrology or backspin detection. No optical fiber port is available. The relay provides protection and monitoring for three-phase motors and their associated systems. The 369 can “learn” individual motor parameters and adjust them for individual applications. To improve the protection of the relay, the user can adjust the motor surge current, cooling rate and/or acceleration time. If you have any questions about this part or series, please contact AX Control.

Protection features on relays include automatic undervoltage restart, reverse power, starter failure, kVA requirement, kvar requirement, kW requirement, current requirement, reverse detection, self-test/service, travel counter, RRTD communication loss, RTD disconnect/disconnect, RTD Short circuit/low temperature, ambient RTD, acceleration timer, mechanical plugging, restart block (reverse meter) Timer), start suppression (available heat capacity), heat capacity, reactive power, main switch, differential switch, lock, Over/under frequency, alarm, hourly start between starts, over voltage protection, power factor, overload protection, ground fault and ground fault backup, short circuit and backup, stator RTD, voltage phase reversal, current imbalance protection, bearing RTD, undercurrent/underpower protection, undervoltage protection, and speed switches.

GE IC670GBI002 distributed I/O connector

GE IS200TSVCH1A
GE IS200TSVCH1AJE
GE IS200TTURH1CFD
GE IS200TVBAH2ACC
GE IS200VTCCH1CBB
GE IS200WNPSH1ABA
GE IS210AEBIH1BED
GE IS210AEBIH3BED
GE IS210AEDBH4AGD
GE IS210AEPSG1AFC
GE IS210SAMBH2AA
GE IS210WSVOH1AE
GE IS215ACLEH1A
GE IS215ACLEH1AB
GE IS215ACLEH1BB
GE IS215UCVEH2AB
GE IS215UCVEH2AF
GE IS215UCVFH2BB VMIVME-7650-83H 350-007650-83H C
GE IS215UCVGM06A IS215UCVGH1A VMIVME-7666-111000
GE IS220PAICH1A
GE IS220PAOCH1A
GE IS220PDIAH1B
GE IS220PDIIH1B 336A5026ADP1
GE IS220PPDAH1B

 

Scroll to Top