9907-810 woodward505 governor
The 9907-810 505 governor is a on-site configuration steam turbine control system, and its operation control panel is integrated with it. On the front panel of the 505, there are two lines of display (single line 24 words) and a comprehensive operation control panel (0CP) with 30 control keys. When in use, simply press the operation prompts on the panel display
By operating the information, it is possible to configure the 505 governor, debug online programs, and calibrate the steam turbine
With regular operation, the operator can also observe the actual measurement data and set values from the screen.
(2) Turbine control parameters
The 9907-810 505 governor can simultaneously control two parameter data, that is, control one of the main parameters and limit the other
Parameters (if required). Generally speaking, the main control parameter is speed (or load), which can be controlled through 505
The parameters for controlling and limiting include: turbine inlet pressure or flow rate, outlet pressure (back pressure) and flow rate, and
Motor output power, device input and output levels, compressor inlet and outlet pressure and flow rate, device factory
The power consumption frequency, process temperature, or any other operating parameters related to the steam turbine, etc.
(3) Communication
The 9907-810 505 governor can directly communicate with the device DCS and CRT control panel through two MODBUS communication ports
For communication, the communication port supports and uses RS-232, RS-422, and
Or RS-485 for communication, and the PID parameters of 505 can be controlled through analog signals, so
Resolution and control will not be affected.
(4) Reliable unit startup and self-protection interlocking functions
The 505 governor also has functions such as unit start and self protection interlocking: automatic start sequence (hot and cold start)
Critical speed avoidance (high and low critical speed), dynamic characteristics of two speeds (load), maximum speed during overspeed tripping
Speed display, priority trip shutdown and display (5 trip inputs in total), and synchronous load sharing with each unit (via
DSLC can achieve self protection of the unit in a fault state.
(5) Use of 505 governor
The 505 governor has two normal operating modes: programming mode and operating mode. Programming mode for adjusting speed
Once the control configuration of the governor is completed, programming mode will no longer be used unless the steam turbine is used
The compressor or operating requirements have changed and need to be reconfigured again. After the configuration is completed, the operating mode can be used for steam control
The engine is controlled (from startup to shutdown). In addition, the 505 governor can also use maintenance mode
Perform online adjustments.
Other relevant models:
WOODWARD | 8237-1006 |
WOODWARD | 8200-1300 |
WOODWARD | 5501-471 |
WOODWARD | 5501-470 |
WOODWARD | 5501-467 |
WOODWARD | 5466-409 |
WOODWARD | 5466-316 |
WOODWARD | 5466-258 |
WOODWARD | 5464-414 |
WOODWARD | 2301E 8273-1011 |
WOODWARD | 8200-1302 |
WOODWARD | 9907-1290 |
WOODWARD | 5233-2089 |
WOODWARD | 9907-810 |
WOODWARD | 5448-906 REV:SPM-D10 |
WOODWARD | 9907-1106 |
WOODWARD | 8440-1706 |
WOODWARD | 5453-203 |
WOODWARD | 5453-277 |
WOODWARD | 5501-381 |
WOODWARD | 5453-279 |
WOODWARD | 5466-318 |
WOODWARD | 5466-425 |
WOODWARD | 8440-1706 A SPM-D11 |
WOODWARD | 5441-693 |
WOODWARD | 9907-018 |
WOODWARD | 9907-018 2301A |
WOODWARD | 2301A 9907-018 |
WOODWARD | 9907-019 |
WOODWARD | 9907-1183 |
WOODWARD | 9907-1200 |
WOODWARD | 9907-205 |
WOODWARD | 8440-1546 H |
WOODWARD | 8440-1706 A |
WOODWARD | 8440-1706 B |
WOODWARD | SPM-D11 |
WOODWARD | SPM-D11 8440-1706B |
WOODWARD | 8440-1713 |
WOODWARD | 8440-1849 D |
WOODWARD | 8440-2165 SPM-D2-11 |
WOODWARD | 8444-1019F |
WOODWARD | 8521-0312 UG-10D |
WOODWARD | EGCP-2 8406-121 |
WOODWARD | 9907-175 |
WOODWARD | 9905-001 SPM-A |
WOODWARD | 9905-020 |
WOODWARD | 9905-144 |
WOODWARD | 9905-726 |
WOODWARD | 9662-810 |
WOODWARD | 9671-810 |
WOODWARD | 9561-810 |
WOODWARD | 9563-810 |
WOODWARD | 8237-1246 |
WOODWARD | 8273-126 |
WOODWARD | 8290-191 |
WOODWARD | 8200-226 |
WOODWARD | 5466-348 |
WOODWARD | 8440-2165 |
WOODWARD | 9907-1349 |
WOODWARD | 9907-1228 |
WOODWARD | 9907-1199 |
WOODWARD | 9907-1198 |
WOODWARD | 9907-1197 |
WOODWARD | TG-13 |
WOODWARD | EASYGEN-3500-5 |
WOODWARD | 8273-140 2301D |
WOODWARD | 8290-194 |
WOODWARD | 5501-432 |
Main product:
ABB:Industrial robot spare parts DSQC series,Bailey INFI 90,IGCT,etc.,for example:5SHY6545L0001 AC10272001R0101 5SXE10-0181,5SHY3545L0009,5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101,PM866,PM861K01,PM864,PM510V16,PPD512 a10-15000 3BHE040375R1023,PPD113,PP836A,PP865A,PP877,PP881,PP885,etc.,
GE:spare parts such as modules,cards,and drivers.For example:VMIVME-7807,VMIVME-7750,WES532-111,UR6UH,SR469-P5-HI-A20,IS230SRTDH2A,IS220PPDAH1B,IS215UCVEH2A,IC698CPE010,IS200SRTDH2ACB,etc.,
Bently Nevada:3500/3300/1900 system,Proximitor probe,etc.,for example:3500/22M,3500/32,3500/15,3500/20,3500/42M,1900/27,etc.,
Invensys Foxboro:I/A series of systems,FBM sequence control,ladder logic control,incident recall processing,DAC,input/output signal processing,data communication and processing,such as FCP270 and FCP280,P0904HA,E69F-TI2-S,FBM230/P0926GU,FEM100/P0973CA,etc.,
Invensys Triconex:power module,CPU Module,communication module,Input output module,such as 3008,3009,3721,4351B,3805E,8312,3511,4355X,etc.,
Woodward:SPC position controller,PEAK150 digital controller,such as 8521-0312 UG-10D,9907-149,9907-162,9907-164,9907-167,TG-13(8516-038),8440-1713/D,5466-258,8200-226,etc.,
Westinghouse/Emerson:OVATION system,WDPF system,MAX1000 system spare parts,such as 1C31129G03,5X00063G01,5X00063G01,1C31181G01,SE3007,VE3008,etc
Rockwell Allen-Bradley:Logix 1756,1794,2711touch screen such as 2711-B6C20,etc.,
Rockwell ICS TRIPLEX:T8151B,T8311,T8403,T9431,T8480C,etc.,
Rockwell Reliance:PLC-MODULE,WR-D4007,0-57406-E,Y-3023-2-H00AA,etc.,
Schneider Modicon:Quantum 140 series processor,control card,power module,
such as 140CPU65160,140CPU67160,140CPU43412,140CPU67060,140DDI35300,140ACO13000,140CRA93100,140CPU11303,140ACO13000,etc.,
Hima:Security modules,such as F8650E,F8652X,F8627X,F8628X,F3236,F6217,F6214,Z7138,F8651X,F8650X,etc.,
Honeywell:all DCS cards,modules,CPUS,such as:CC-MCAR01,CC-PAIH01,CC-PAIH02,CC-PAIH51,CC-PAIX02,CC-PAON01,CC-PCF901,TC-CCR014,TC-PPD011,CC-PCNT02,etc.,
Motorola:MVME162,MVME167,MVME172,MVME177 series,such as MVME5100,MVME5500-0163,VME172PA-652SE,VME162PA-344SE-2G,etc.,
Xycom:I/O,VME board and processor,for example,XVME-530,XVME-674,XVME-957,XVME-976,etc.,
Kollmorgen:Servo drive and motor,such as S72402-NANANA,S62001-550,S20330-SRS,CB06551/PRD-B040SSIB-63,etc.,
Bosch/Rexroth/Indramat:I/O module,PLC controller,driver module,MSK060C-0600-NN-S1-UP1-NNNN,VT2000-52/R900033828,MHD041B-144-PG1-UN,etc.,
More…
PLC-Module.com|XiongBa Industrial Control|Panda|ABB 5SHY3545L0014
PREVIOUS:ABB GVC750BE101 3BHE009681R0101 IGCT ModuleNEXT:ABB GVC736BE101 3BHB019719R0101 ACS 6000 IGCT