T8403C Trusted TMR 24V dc Digital Input ICS TRIPLEX
T8403C Trusted TMR 24V dc Digital Input ICS TRIPLEX
Brand Name | ICS Triplex |
Model | T8403C |
Product type | N/M |
Condition | New |
Gross Weight | 1kg |
Packing Size | 12.6″ x 7.9″ x 8.8″ (30 cm x 20 cm x 20 cm) |
Country of Origin | USA |
Lead Time | In Stock |
Shipping Port | Xiamen |
Payment | T/T |
Sales Price | Inquiry |
Color | Depends on material |
Warranty | 12 months |
Lead time | 3-7 work days |
Courier partners | FedEx,DHL, UPS, TNTand EMS |
T8403C Trusted 40 Channel Analogue Input FTA
Product Overview
The Trusted® 40 Channel Analogue Input Field Termination Assembly (FTA) T8830 is designed to act
as the main interface between a field device generating an analogue signal and the Trusted TMR
Analogue Input Module T8403C
Features:
• 40 input channels per FTA.
• Industry standard field device connections (2-wire).
• Standard DIN rail compatibility.
• Simple installation and connection.
• 24 Vdc operation.
• SmartSlot connection for ‘one to many’ hot replacement of input modules.
• Fused field power supply per channel.
• On-board Light Emitting Diode (LED) indication of field power supply integrity.
T8403C Installation
Trusted 40 Channel Analogue Input FTA T8830 is designed to be mounted on either of the
TS32 or TS35 DIN rails in the horizontal or vertical positions as required.
T8160 Serial Ports
There are two connectors available to access the RS232 ports. Bank 1 provides a full RS232
interface. Bank 2 provides a partial RS232 interface with connections limited to TX, RX, RTS
and CTS.
Serial Ports
1. There are eight connectors available to directly access the four RS485 ports. Banks 1
and 2 cannot be used in the RS485 mode if the Trusted Communication Interface is
configured for RS232 on these ports.
2. The RS485 ports are provided with two connectors per port. Each port is provided
with link selectable 120 Ω alternating current (ac) termination on both the transmit
and receive circuits as shown in the table below.
3. The ac coupled termination is used so as to reduce the current drawn on the
transmission line during the idle state. The use of two connectors and link selectable
termination is to make the configuration of multiplexed transmission lines simpler.
This method also provides the termination close to the transceivers thus avoiding
unnecessary reflections on the line.
2.3. Examples
RS485 FULL DUPLEX LINK
This is a point to point 4 wire link. The connections to the Termination Assembly should be
to Connector 1 with the TX/RX Termination link fitted.
RS485 FULL DUPLEX MULTIPLEXED
This is the most complicated system.
If the Termination Assembly is at the start of the multiplexed chain then Connector 1 is used
and the TX/RX Termination link is fitted.
If the Termination Assembly is in the chain then the Connector 1 is used to connect the
chain in and connector 2 is used to wire out to the next device. No links are fitted for this
port.
If the Termination Assembly is the last device in the chain Connector 1 is used and both the
TX Termination Link and the TX/RX Termination Link are fitted. The TX Termination link is
used here so that both ends of the line with multiple transmitters connected are
terminated.
RS485 Half Duplex Multiplexed
This is the 2 wires 485 system that is only wired on the RX/TX wires.
If the Termination Assembly is at the start or end of the transmission line Connector 1 is
used and the TX/RX Termination link is fitted.
If the Termination Assembly is in the transmission line then Connector 1 is used to connect
the chain in and Connector 2 is used to wire out to the next device. No links are fitted for
this port.
2.4. RS485 Hints
The signal ground on the RS485 links must always be connected otherwise the
communications between the devices may be unreliable. When specifying cable for these
connections allowance should be made for the signal ground connection. If screened cable
is used the signal ground should not be connected to the screen. It is usual to connect the
screen to the chassis earth at one end only.
Some manufacturers tend to use + and – designations on their equipment for labelling the
pairs. Since there is no standard as to how these match up with the EIA circuit designators
the following may be useful:
With the transmission line in the ‘Idle’ or ‘Off’ state connect a multimeter on the
volts range across the pair. When the multimeter reads a negative voltage the +ve
terminal of the multimeter is connected to A and the –ve terminal is connected to B.
2.5. Ethernet ports
Ethernet ports 1 (TCP/IP 0) on J6 and 2 (TCP/IP 1) on J8 are provided with connections to
10/100BaseT networks via RJ45 connectors.
T8310 | Trusted Expander Processor |
T9801 | Digital input TA 16 channel, simplex commoned |
T9310-02 | Backplane expansion cable, 2 metre |
T9882 | Analogue output TA 8 channel, dual, isolated |
T9191 | Blanking cover (al) for I0 positions with no TA ftted |
T9030 | OPC portal server |
T8312-4C | Trusted Expander Interface Adaptor – 4 Way |
T9832 | Analogue input TA 16 channel, dual, isolated |
T8312-7C | Trusted Expander Interface Adaptor – 7 Way |
T9833 | Analogue input TA 16 channel, TMR, isolated |
T9802 | Digital input TA 16 channel, dual, isolated |
T9881 | Analogue output TA 8 channel, simplex isolated |
T8300C | Trusted Expander Chassis |
T8123C | Trusted TMR Processor Interface Adaptor, (IRG-B and MODBUS Master) |
T8122C | Trusted TMR Processor Interface Adaptor (MODBUS Master) |
T9852 | Digital output TA 24Vdc, 8 channel, dual, commoned |
T8153C | Trusted Communication Interface Adaptor |
T8121C | Trusted TMR Processor Interface Adaptor (IRIG_-B) |
T9087 | AADVANCE WORKBENCH 2 |
T8111C | Trusted TMR Processor |
T9803 | Digital input TA 16 channel, TMR, isolated |
T8311C | Trusted Expander Interface |
T9851 | Digital output TA 24Vdc, 8 channel, simplex, commoned |
T9831 | Analogue input TA 16 channel, simplex, commoned |
T8100C | Trusted Controller Chassis |
T9083U | IEC 61131 Workbench, USB key, multiple controllers |
T9082U | IEC 61131 Workbench, USB key, single user, single controller |
T9082D | IEC 61131 Workbench, hard disk key, single user, single controller |
T9901 | AAdvance 20 Replacement In fuse 50mA |
T9083D | IEC 61131 Workbench, hard disk key, multiple controllers |
T9084U | IEC 61131 Workbench, 5 user USB key, multiple controllers |
T9902 | AAdvance 20 Replacement Out fuse 10A |
T9482 | Analogue output module, 8 channel, isolated |
T9193 | Blanking cover (short) for I0 positions with TA or a Processor |
T8151C | Trusted Communication Interface |
T8120C | Trusted TMR Processor Interface Adaptor |
T9100 | Processor base unit |
T9300 | /O base unit |
T9110 | Processor module |
T9401 | Digital input module, 24Vdc, 8 channel, isolated |
T9402 | Digital input module, 24Vdc, 16 channel, isolated |
T9451 | Digital output module, 24Vdc, 8 channel, commoned |
T9431 | Analogue input module, 8 channel, isolated |
T9432 | Analogue input module, 16 channel, isolated |
T9481 | Analogue output module, 3 channel, isolated |
T8314C | Trusted Fibre TX RX Unit |
T8403C | Trusted TMR 24V dc Digital Input一40 channel |
T8431C | Trusted TMR Analogue Input一40 channel |
T8451C | Trusted TMR 24V dc Digital Output一40 channel |
T8461C | Trusted TMR 24/48V dc Digital Output – 40 channel |
T8472C | T8472 Trusted TMR 120VAC Digital Output Module |
T8480C | Trusted TMR Analogue Output – 40 channel |
T8442C | Trusted Speed Monitor |
T8800C | Trusted 40 channel 24V dc Digital Input FTA |
T8830C | Trusted 40 channel Analogue Input FTA |
T8850C | Trusted 40 channel Analogue or Digital Output FTA |
T8231 | Trusted 9 channel Speed Input FTA |
T8891C | Trusted 2 channel High Integrity Relay Output FTA |
T8290C | Output Power Distribution Module |
T8292C | Power Distribution Unit, MCB 24V dc |
T8293C | Power Distribution Module 15 Way Fuse |
T8191 | Trusted Shield, (For 1/0 and Communication Modules一Single Slot)- Pack of 6 |
T8193 | Trusted Shield (For Controller Module一Triple Slot)一Pack of 2 |
T8194 | Shroud Kit for T8290 or T8297 |
T8270 | 24V dc Fan Assembly, Rack Mounting (Includes 1-off T8273) |
T8271 | Trusted Fan Tray 24V dc Roof Mounted |
T8272 | Trusted Vent & Bafle Unit for Fan Assembly |
T8273 | Grill for Fan Assembly, Rack Mounting |
T8380 | Chassis Panel Rear Mounting Kit |
T8901 | VFTA Fuse/L ink Pack (10 off 50MA 10 off 315MA& 10 off 2A) |
T8902 | FTA 40 channel, Fuse Pack (10 off 50MA) |
T8903 | FTA 60 channel, Fuse Pack (10 off 50MA) |
TC-001-02-1M5 | Chassis Power cable, 1 .5m (5ft) |
TC-001-02-2M5 | Chassis Power cable, 2.5m (8ft) |
TC-001-02-6M5 | Chassis Power cable, 6.0m (20ft) |
TC-002-02-2M5 | Power cable T8292 to T8293, 2.5 metre (8ft) |
TC-003-02-2M5 | Power cable T8293 and input FTA 25m (8ft) |
TC-011-02-1M5 | Fan Power cable, 1 .5m (5t) |
TC-011-02-4M5 | Fan Power cable, 4 5m (15f) |
TC-011-02-6M0 | Fan Power cable, 6 0m (20ft) |
TC-201-02-2M5 | IO Companion Slot, Internal, 40 channel Input to FTA 2M5 8ft, PVC |
TC-201-02-4M5 | IO Companion Slot, Internal, 40 channel Input to FTA 4M516ft, PVC |
TC-201-02-6M5 | IO Companion Slot, Internal, 40 channel Input to FTA 6M5, 21ft, PVC |
TC-201-02-8M5 | IO Companion Slot, Internal, 40 channel Input to FTA 8M5, 28ft, PVC |
TC-201-02-10M5 | IO Companion Slot, Internal, 40 channel Input to F TA 10M5, 34t, PVC |
TC-201-02-12M5 | IO Companion Slot, Internal, 40 channel Input to FTA 12M5, 40ft, PVC |
TC-203-02-4M5 | IO Companion Slot, External, 40 channel Input to FTA 4M5 |
TC-203-02-6M5 | IO Companion Slot, External, 40 channel Input to FTA 6M5 |
TC-203-02-8M5 | IO Companion Slot, External, 40 channel Input to FTA 8M5 |
TC-203-02-10M5 | IO Companion Slot, External, 40 channel Input to FTA 10M5 |
TC-203-02-12M5 | IO Companion Slot, External, 40 channel Input to FTA 12M5 |
TC-205-02-4M5 | IO Companion Slot, Internal, 40 channel Output to FTA 4M5 |
TC-205-02-6M5 | IO Companion Slot, Internal, 40 channel Output to FTA 6M5 |
TC-205-02-8M5 | IO Companion Slot, Internal, 40 channel Output to FTA 8M5 |
TC-205-02-10M5 | IO Companion Slot, Internal, 40 channel Output to FTA 10M5 |
TC-205-02-12M5 | IO Companion Slot, Internal, 40 channel Output to FTA 12M5 |
TC-215-02-4M5 | IO Companion Slot, Internal, 40 channel Output to FTA 4M5 |
TC-215-02-6M5 | IO Companion Slot, Internal, 40 channel Output to FTA 6M5 |
TC-215-02-8M5 | Trusted Cable |
TC-215-02-10M5 | Trusted Cable |
TC-215-02-12M5 | Trusted Cable |
TC-301-02-2M0 | Local Expansion Cable, 2.0m(6.5 ft) |
TC-301-02-2M5 | Local Expansion Cable, 2.5m (8 ft) |
TC-301-02-4M5 | Local Expansion Cable, 4.5m(15 ft) |
TC-301-02-6M5 | Local Expansion Cable, 6.5m (21t) |
TC-302-02-4M0 | Remote Expander Cable (Controller End), 4.0m (13 ft) |
TC-303-02 4M0 | Remote Expander Cable (Expander End), 4.0m (13 ft) |
TC-304-01 | Trusted Remote Expansion Cable Exp End |
TC-305-01 | TRUSTED COMMS CABLE FL |
TC-311-02 | Local Expansion Cable Assembly, 1 way (2M0) |
TC-312-02 | Local Expansion Cable Assembly, 2 way (2M0 & 2M5) |
TC-313-02 | Local Expansion Cable Assembly, 3 way (2MO, 2M5 & 3M0) |
TC-314-02-2M5 | Expander Extension Cable, Single Slice |
TC-801-02-4M5 | IO Companion Slot, Speed Monitor to FTA (internal), 4M5 |
TC-801-02-6M5 | IO Companion Slot, Speed Monitor to FTA (internal), 6M5 |
TC-011-02-2M5 | TRUSTED FAN POWERCABL .E |